Model NO.: BK-GC102AF Ray Type: Gamma Ray Spectrometer Detector: FID Certification: CE, ISO Mobile Phase: Gas Chromatographic Column Type: Capilary Column Temperature Control Range: 15-399 Degree Above Room Temperature Temperature Control Objects: Column, Ion Chamber, Thermal Conductivity, Sampler Temperature Programming Rate: 0.1-40 Degree/Min(Increment by 0.1 Degree) Dimension: 575-480-490mm Gross Weight: 120kg Trademark: BIOBASE Origin: China Appliance: The Analysis of Environmental Samples Gaspath System: Double Energy Resolution: ≤7.5% Stationary Phase: Liquid Solvent Chromatography Type: Gas Chromatography Chromatographic Column Diameter: 0.53mm Temperature Increment by: 1 Degree Temperature Programming Phase: Five Flame Ionization Detector: Fid Net Weight: 100kg Linear Range: ≥106 Specification: CE, ISO FEATURES:
PC control, user-friendly interface, and easy to operate.
Temperature control is of high accuracy (better than ±0.1ºC). Heating speed is fast and overshoot temperature is small.
Self-diagnosis, power protection, oven over-temperature protection, and automatic ignition.
It can accurately display the temperature control settings, actual value, and FID amplifier sensitivity.
The single gas system and precise scale pneumatic control valve contribute to excellent reproducibility and stability and can perform analysis of packed column or capillary with wide diameter of 0.53mm.
Packed column: on-column injection, instantaneous vaporization injection, gas injection.
Open computer system and NJ2000 chromatography workstation can work together to process data. Large capacity oven (300mm×280mm×270mm) facilitates the installation of packed column and capillary. Built-in heating wire structure.
Technical specifications:
Item | Gas Chromatograph |
Model | BK-GC102AF |
Chromatography Type | Gas Chromatography |
Voltage | 220V~±22V 50Hz±0.5Hz |
Power | ≤1500W |
Dimensions | 575mm (L) * 480 (W) * 490mm (H) |
Weight | 50kg |
Mobile Phase | Gas |
Detector | FID |
Max. Limit Temperature | 400ºC |
Linear Range | ≥106 |
Baseline Drift | ≤2×10-12A/h |
Detection Limit | Dt≤1×10-10g/s (octane and hexadecane) |
Temperature Accuracy | Better than ±0.1ºC (measured at 200ºC) Flame Ionization Detector (FID) |
Temperature Range | 15ºC ~399ºC above room temperature (increment: 1ºC) |
Temperature Area | Column oven, sampler, detector |
Optional:
NJ2000 chromatography workstation
Contact us if you need more details on Gas Chromatograph. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Gas Chromatography、
Laboratory Equipment. If these products fail to match your need, please contact us and we would like to provide relevant information.